Associate Professor Dale Bailey
|
Associate Professor Imaging, Northern Clinical School
E25 - Royal North Shore Hospital
The University of Sydney
NSW 2006 Australia
|
|
On this page
Biographical details | Research interests | Grants | Publications
Biographical details
My interests are in the development of quantitative techniques using imaging of in vivo radionuclide tracers and development of multi-modality imaging methodology. I have extensive experience in both single photon tomography (SPECT) and positron emission tomography (PET). Contributions include developing simultaneous emission/transmission scanning on the gamma camera using the scanning radionuclide line source approach, which has now been implemented by nearly all manufacturers and, more recently, leading a team in developing an in-house SPECT/CT scanner. I have had numerous clinical collaborations most notably in functional neuro-imaging and in respiratory medicine. I was actively involved in developing techniques to measure cerebral activation in PET, assessing aerosol distribution in vivo using 3D methods, measuring changes in mucus clearance rates after therapeutic interventions, and in mapping airways ventilation patterns. More recently, I have been involved in developing techniques and instrumentation for SPECT/CT multimodality imaging and investigating novel methods of measuring and utilising measures of error variance in reconstructed SPECT & PET images.
Research interests
SPECT/CT (Single Photon Emission Computred Tomography)
Lung imaging of ventilation and perfusion
PET/CT (Positron Emission Tomography)
Analysis of reconstructed image characteristics and variance properties
Current national competitive grants*
2008
Determination of the clinical correlates of lymphoedema: a pilot study
Kilbreath S, Ward L, Refshauge K, Baldock C, Bailey D, Giuffre B, Lee M
National Breast Cancer Foundation Pilot Study Grants ($118,424 over 2 years)
* Grants administered through the University of Sydney
Publications
2008
Roach, P., Bailey, D., Schembri, G. Reinventing ventilation/perfusion lung scanning with SPECT. Nuclear Medicine Communications. 2008; 29:1023-1025. [Abstract]
Roach, P., Bailey, D., Harris, B. Enhancing lung scintigraphy with single-photon emission computed tomography. Seminars in nuclear medicine. 2008; 38:441-449. [Abstract]
Brown, S., Bailey, D., Willowson, K., Baldock, C. Investigation of the relationship between linear attenuation coefficients and CT Hounsfield units using radionuclides for SPECT. Applied Radiation and Isotopes. 2008; 66:1206-1212. [Abstract]
Willowson, K., Bailey, D., Baldock, C. Quantitative SPECT reconstruction using CT-derived corrections. Physics in medicine and biology. 2008; 53:3099-112. [Abstract]
Bailey, D., Schembri, G., Harris, B., Bailey, E., Cooper, R., Roach, P. Generation of planar images from lung ventilation/perfusion SPECT. Annals of nuclear medicine. 2008; 22:437-445. [Abstract]
Harris, B., Bailey, D., Roach, P., Schembri, G., Hoshon, I., Chicco, P., Bailey, E., King, G. A clinical comparison between traditional planar V/Q images and planar images generated from SPECT V/Q scintigraphy. Nuclear Medicine Communications. 2008; 29:323-330. [Abstract]
Harris, B., Bailey, D., Chicco, P., Bailey, E., Roach, P., King, G. Objective analysis of whole lung and lobar ventilation/ perfusion relationships in pulmonary embolism. Clinical physiology and functional imaging. 2008; 28:14-26. [Abstract]
2007
Bailey, D., Roach, P., Bailey, E., Hewlett, J., Keijzers, R. Development of a cost-effective modular SPECT/CT scanner. European journal of nuclear medicine and molecular imaging. 2007; 34:1415-26. [Abstract]
Harris, B., Bailey, D., Miles, S., Bailey, E., Rogers, K., Roach, P., Thomas, P., Hensley, M., King, G. Objective analysis of tomographic ventilation-perfusion scintigraphy in pulmonary embolism. American journal of respiratory and critical care medicine. 2007; 175:1173-1180. [Abstract]
Bailey, D. Attentuation Correction in PET and SPECT. In: Clinical Nuclear Medicine. United Kingdom: Hodder Arnold 2007. p. 0.
Harris, B., Bailey, D., Roach, P., Bailey, E., King, G. Fusion imaging of computed tomographic pulmonary angiography and SPECT ventilation/perfusion scintigraphy: initial experience and potential benefit. European journal of nuclear medicine and molecular imaging. 2007; 34:135-142. [Abstract]
2006
Roach, P., Schembri, G., Ho Shon, I., Bailey, E., Bailey, D. SPECT/CT imaging using a spiral CT scanner for anatomical localization: Impact on diagnostic accuracy and reporter confidence in clinical practice. Nuclear medicine communications. 2006; 27:977-87. [Abstract]
Ladd, L., Tinworth, K., Bailey, D., Bautovich, G., Bailey, E., Roach, P., Hunyor, S. SPECT/CT imaging for tracking myocardial infarction (MI) in an ovine model. Journal of Molecular and Cellular Cardiology. 2006; 41:739-739. [Abstract]
Robertson, A., Roach, P., Shields, M., Bailey, D. Tc-99m sestamibi myocardial perfusion imaging after undisclosed I-131 therapy. Journal of nuclear cardiology. 2006; 13:722-724. [Abstract]
Harris, B., Bailey, D., Roach, P., Marshman, D., McElduff, A., King, G. Use of fusion imaging to localize an ectopic thoracic parathyroid adenoma. The Annals of thoracic surgery. 2006; 82:719-21. [Abstract]
Livieratos, L., Rajappan, K., Stegger, L., Schafers, K., Bailey, D., Camici, P. Respiratory gating of cardiac PET data in list-mode acquisition. European journal of nuclear medicine and molecular imaging. 2006; 33:584-588. [Abstract]
Valk, P., Delbeke, D., Bailey, D., Townsend, D., Maisey, M. Positron Emission Tomography: Clinical Practice. United Kingdom: Springer, 2006.
Bailey, D. Imaging the airways in 2006. Journal of aerosol medicine : the official journal of the International Society for Aerosols in Medicine. 2006; 19:1-7. [Abstract]
2005
Roach, P., Bailey, D. Combining anatomy and function: the future of medical imaging. Internal medicine journal. 2005; 35:577-9. [Abstract]
Thomas, M., Bailey, D., Livieratos, L. A dual modality approach to quantitative quality control in emission tomography. Physics in medicine and biology. 2005; 50:N187-94. [Abstract]
Livieratos, L., Stegger, L., Bloomfield, P., Schafers, K., Bailey, D., Camici, P. Rigid-body transformation of list-mode projection data for respiratory motion correction in cardiac PET. Physics in medicine and biology. 2005; 50:3313-22. [Abstract]
Bailey, D., Kalemis, A. Externally triggered gating of nuclear medicine acquisitions: a useful method for partitioning data. Physics in medicine and biology. 2005; 50:N55-62. [Abstract]
Skrypniuk, J., Bailey, D., Cosgriff, P., Fleming, J., Houston, A., Jarritt, P., Whalley, D. UK audit of left ventricular ejection fraction estimation from equilibrium ECG gated blood pool images. Nuclear medicine communications. 2005; 26:205-15. [Abstract]
Bailey, D., Townsend, D., Valk, P., Maisey, M. Positron Emission Tomography: Basic Science. United States: Springer, 2005.
Bailey, D., Townsend, D., Maisey, M., Valk, P. Positron Emission Tomography: Basic Science. London: Springer-Verlag, 2005.
2004
Fleming, J., Whalley, D., Skrypniuk, J., Jarritt, P., Houston, A., Cosgriff, P., Bailey, D. UK audit of relative lung function measurement from planar radionuclide imaging. Nuclear medicine communications. 2004; 25:923-34. [Abstract]
Kalemis, A., Bailey, D., Flower, M., Lord, S., Ott, R. Statistical pixelwise inference models for planar data analysis: an application to gamma-camera uniformity monitoring. Physics in medicine and biology. 2004; 49:3047-66. [Abstract]
Whone, A., Bailey, D., Remy, P., Pavese, N., Brooks, D. A technique for standardized central analysis of 6-(18)F-fluoro-L-DOPA PET data from a multicenter study. Journal of nuclear medicine : official publication, Society of Nuclear Medicine. 2004; 45:1135-45. [Abstract]
Bailey, D., Snowdon, G., Cooper, R., Roach, P. The use of molecular sieves to produce point sources of radioactivity. Physics in medicine and biology. 2004; 49:N21-9. [Abstract]
Marx, G., Blake, G., Galani, E., Steer, C., Harper, S., Adamson, K., Bailey, D., Harper, P. Evaluation of the Cockroft-Gault, Jelliffe and Wright formulae in estimating renal function in elderly cancer patients. Annals of oncology. 2004; 15:291-5. [Abstract]
Valk, P., Bailey, D., Townsend, D., Maisey, M. Positron Emission Tomography: Basic Science and Clinical Practice. United Kingdom: Springer, 2004.
2003
Bailey, D. Is PET the future of nuclear medicine?. European journal of nuclear medicine and molecular imaging. 2003; 30:1047-9. [Abstract]
Kalemis, A., Binnie, D., Bailey, D., Flower, M., Ott, R. Scaling images using their background ratio. An application in statistical comparisons of images. Physics in medicine and biology. 2003; 48:1539-49. [Abstract]
Bailey, D., Karp, J., Surti, S. Physics and instrumentation in PET: Basic Science and Clinical Practice. In: Positron Emission Tomography. London: Springer-Verlag 2003. p. 41-67.
Bailey, D. Data acquisition and performacne characterization in PET. In: Positron Emission Tomography. London: Springer-Verlag 2003. p. 69-90.
Hawkes, D., Hill, D., Hallpike, L., Bailey, D. Coregistration of structural and functional images. In: Positron Emission Tomography. London: Springer-Verlag 2003. p. 181-197.
Bailey, D., Adamson, K. Nuclear medicine: from photons to physiology. Current pharmaceutical design. 2003; 9:903-16. [Abstract]
Bailey, D. Is PET the future of nuclear medicine? Against. European Journal Of Nuclear Medicine And Molecular Imaging. 2003; 30(7):1046-1049.
2002
Rakshi, J., Pavese, N., Uema, T., Ito, K., Morrish, P., Bailey, D., Brooks, D. A comparison of the progression of early Parkinson's disease in patients started on ropinirole or L-dopa: an 18F-dopa PET study. Journal of neural transmission (Vienna, Austria : 1996). 2002; 109:1433-43. [Abstract]
Ceravolo, R., Piccini, P., Bailey, D., Jorga, K., Bryson, H., Brooks, D. 18F-dopa PET evidence that tolcapone acts as a central COMT inhibitor in Parkinson's disease. Synapse (New York, N.Y.). 2002; 43:201-7. [Abstract]
[Show all 40 publications][Hide publications]